Section 04 — Carbon Accounting & Abatement
Campus Greenhouse Gas Footprint & Avoided Emissions
"In 2024, VIT's gross greenhouse gas emissions totaled 30,757 tonnes CO₂e—with grid electricity comprising 77.9%. Campus vegetative sinks sequester 2,814 t CO₂/yr, yielding net emissions of 27,943 t CO₂e. Clean energy interventions currently avoid 14,500+ tonnes of additional emissions annually."
30,757 t CO₂e
Gross Annual Greenhouse Footprint (Scope 1 + Scope 2)
Environmental Audit 2024, p. 21
2,814.4 t/yr
Sequestration by Campus Trees, Lawn & Open Soil
Green Audit 2023, p. 54
27,942.8 t/yr
Net Annual Campus Emissions (Gross Footprint − Natural Sinks)
Environmental Audit 2024, p. 21
13,103 t/yr
Emissions Avoided Annually via Offsite Wind & Solar Procurement
Calculated @ 0.813 kg/kWh
1. Gross Emissions Breakdown by Source (2024)
Grid-supplied electricity dominates the university's operational emissions footprint. While fuel combustion in 31 backup diesel generators (2,30,000 L/yr), student shuttles (2,83,057 L/yr), and kitchen LPG (16.61 lakh L/yr) contributes 4,246 tonnes CO₂e, purchased electricity represents 23,968 tonnes CO₂e.
Fig. 4.1 — Source distribution of annual gross campus CO₂e emissions (30,757 tonnes total). Source: Environmental Audit Report (2024), p. 21.
2. Avoided Emissions from Sustainable Infrastructure
VIT has invested in four major technical systems that actively displace thermal electricity and direct combustion:
| Intervention | Technology Details | Energy Saved (Annual) | Avoided CO₂ (Annual) | Cost Saved (₹/yr) |
|---|---|---|---|---|
| Contracted Wind Wheeling | 1.22 Cr kWh purchased from Bharat Enterprises & BBK Shoes | 1,22,00,000 kWh | 9,918.6 t | ₹3.63 Cr |
| Rooftop Solar PV | 2.81 MWp rooftop panels producing 37.97 lakh units/yr | 37,97,955 kWh | 3,087.7 t | ₹2.56 Cr |
| District Cooling System | 5,500 TR central chiller plant vs decentralised split ACs | 5,49,418 kWh | 1,531.0 t | ₹44.2 Lakh |
| Heat Pump Hot Water | SES 12T Heat Pumps (COP 4.0) vs electrical resistance | 15,29,775 kWh | 1,392.1 t | ₹1.23 Cr |
| Gandhi Block Cooling | Radiant slab cooling + Indirect Evaporative Cooling (IEC) | 3,14,160 kWh | 12.6 t | ₹21.9 Lakh |
Table 4.1 — Clean technology displacement analysis. Calculated based on 2020 Energy Audit and 2024 Environmental Audit certified savings.
3. Point-Source Emitters & Laboratory Verification
Beyond utility electricity, specific engineering disciplines host localized emission sources identified during field audits:
- Automotive & IC Engine Labs (SMEC): Houses multi-cylinder test rigs and dynamometers burning diesel and petrol fuel blends for experimental combustion analysis. Exhaust is routed through dedicated scrubbers and elevated flues.
- Chemical & Process Engineering Labs (SCHEME / SMV): Operates batch reaction kettles, solvent recovery columns, and thermal units. Organic chemical wastes are safely sequestered in cement chambers and handed to TNPCB-authorized recyclers.
- Emergency DG Sets (31 units, 16.9 MVA): Diesel backup capacity operated during grid failures and monsoon emergencies. Fitted with acoustic enclosures and stack heights up to 24 meters in compliance with CPCB air pollution guidelines.
Greenhouse Accounting Citations
- Scope 1 Fuel Emissions: Diesel generators (2,30,000 L) and transport diesel (2,83,057 L) calculated at 0.00333 t CO₂/L. LPG (16,61,186 L) calculated at 0.00152 t CO₂/L. Environmental Audit Report 2024, p. 21.
- Scope 2 Grid Factor: The audit report applies a conservative 0.813 kg CO₂/kWh factor reflecting Tamil Nadu's legacy thermal fleet, whereas the CEA Version 19 CO₂ baseline for the integrated Southern regional grid documents 0.716 kg CO₂/kWh due to rising regional wind and solar penetration.